Generador DIÉSEL de 7,9 a 43.8 kW
HYW
Powered by YANMAR
Generador DIÉSEL de 100.0 – 745.0 kW
HDW
Powered by DOOSAN


Generador Diésel de 52.0 – 545.0 kW
HFW
Powered by FPT_IVECO
Generador Diésel de 250.0 – 610.0 kW
HMW
Powered by MTU

PLANTA ELECTRICA YANMAR | Consumo Combustible Lt/Hr 75% carga | AMP STBY POWER | Fichas Técnicas | |||||
Modelo | KW | Modelo | ||||||
PRP (1) | STBY (2) | 220 | 440 | Estándar | Insonorizado | |||
HYW-9 T6 | 7,9 | 8,6 | 3TNV76GGEH | 2,21 | 28 | 14 | ||
HYW-14 T6 | 12,2 | 13,2 | 3TNV88BGGEH | 3,06 | 43 | 22 | ||
HYW-20 T6 | 16,5 | 20 | 4TNV88BGGEH | 4,10 | 66 | 33 | ||
HYW-25 T6 | 21 | 23 | 4TNV84TBGGE | 4,90 | 76 | 38 | ||
HYW-35 T6 | 32 | 36 | 4TNV98GGEH | 6,83 | 118 | 59 | ||
HYW-45 T6 | 40 | 44 | 4TNV98TGGEH | 8,61 | 145 | 72 |
PLANTA ELECTRICA | IVECO | Consumo Combustible Lt/Hr 80% carga | AMP STBY POWER | Fichas Técnicas | ||||
Modelo | KW | Modelo | ||||||
PRP (1) | STBY (2) | 220 | 440 | Estándar | Insonorizado | |||
HFW-60 T6 | 52,0 | 57,0 | NEF45SM1A | 11,70 | 187 | 94 | ||
HFW-65 T6 | 58,0 | 64,0 | NEF45SM2A | 13,00 | 210 | 105 | ||
HFW-85 T6 | 72,0 | 88,0 | NEF45SM3 | 15,40 | 289 | 145 | ||
HFW-100 T6 | 88,0 | 97,0 | NEF45TM2A | 19,60 | 319 | 159 | ||
HFW-120 T6 | 112,0 | 123,0 | NEF45TM3 | 19,60 | 404 | 202 | ||
HFW-125 T6 | 116,0 | 127,0 | NEF67TM2A | 28,50 | 417 | 209 | ||
HFW-155 T6 | 138,0 | 152,0 | NEF67TM3A | 32,50 | 499 | 250 | ||
HFW-175 T6 | 160,0 | 175,0 | NEF67TM4 | 32,50 | 575 | 287 | ||
HFW-200 T6 | 181,0 | 200,0 | NEF67TE2A | 38,90 | 657 | 328 | ||
HFW-250 T6 | 233,0 | 255,0 | C87TE1D | 54,00 | 837 | 419 | ||
HFW-290 T6 | 263,0 | 288,0 | C10TE1D | 63,80 | 946 | 473 | ||
HFW-340 T6 | 308,0 | 338,0 | C13TE2A | 67,40 | 1.110 | 555 | ||
HFW-375 T6 | 339,0 | 371,0 | C13TE3A | 82,50 | 1.218 | 609 | ||
HFW-440 T6 | 400,0 | 440,0 | C13TE7 | 87,70 | 1.445 | 723 | ||
HFW-550 T6 | 494,0 | 545,0 | CR16TE1W | 100,12 | 1.790 | 895 |
PLANTA ELECTRICA | DOOSAN | Consumo Combustible Lt/Hr 75% carga | AMP STBY POWER | Fichas Tecnicas | ||||
Modelo | KW | Modelo | ||||||
PRP (1) | STBY (2) | 220 | 440 | Estandar | Insonorizado | |||
HDW-110 T6 | 100,0 | 110,0 | D1146T | 24,90 | 361 | 181 | ||
HDW-200 T6 | 184,0 | 201,0 | P086TI | 37,70 | 660 | 330 | ||
HDW-270 T6 | 248,0 | 266,0 | P126TI | 52,30 | 874 | 437 | ||
HDW-310 T6 | 276,0 | 307,0 | P126TI-II | 56,00 | 1.008 | 504 | ||
HDW-405 T6 | 354,0 | 405,0 | P158LE | 74,70 | 1.330 | 665 | ||
HDW-460 T6 | 416,0 | 459,0 | DP158LCS | 83,40 | 1.507 | 754 | ||
HDW-510 T6 | 453,0 | 515,0 | DP158LDS | 92,90 | 1.691 | 846 | ||
HDW-555 T6 | 507,0 | 555,0 | DP180LAS | 106,60 | 1.823 | 911 | ||
HDW-605 T6 | 548,0 | 604,0 | DP180LBS | 114,20 | 1.984 | 992 | ||
HDW-660 T6 | 600,0 | 655,0 | DP222LAS | 120,40 | 2.151 | 1.076 | ||
HDW-710 T6 | 640,0 | 706,0 | DP222LBS | 127,70 | 2.319 | 1.159 | ||
HDW-745 T6 | 676,0 | 745,0 | DP222LCS | 134,40 | 2.447 | 1.223 |
PLANTA ELECTRICA | MTU | Consumo Combustible Lt/Hr 75% carga | AMP STBY POWER | Fichas Técnicas | ||||
Modelo | KW | Modelo | ||||||
PRP (1) | STBY (2) | 220 | 440 | Estándar | Insonorizado | |||
HMW-270 T6 | 250,0 | 275,0 | 6R1600G10S | 55,48 | 903 | 452 | ||
HMW-310 T6 | 279,0 | 306,0 | 6R1600G20S | 58,77 | 1.005 | 502 | ||
HMW-370T6 | 337,0 | 371,0 | 8V1600G10S | 77,00 | 1.218 | 609 | ||
HMW-405 T6 | 372,0 | 407,0 | 8V1600G20S | 79,35 | 1.337 | 668 | ||
HMW-510 T6 | 463,0 | 508,0 | 10V1600G20S | 90,02 | 1.668 | 834 | ||
HMW-555 T6 | 508,0 | 555,0 | 12V1600G10S | 100,78 | 1.823 | 911 | ||
HMW-615 T6 | 554,0 | 610,0 | 12V1600B40S | 104,99 | 2.003 | 1.002 |
(1) P.R.P. Prime Power – ISO 8528: es la potencia máxima disponible para un ciclo de potencia variable que puede ocurrir por un número ilimitado de horas por año, entre periodos de mantemientos señalados . La potencia media consumible durante un periodo de 24 horas no debe rebasar el 80% de la P.R.P. 10% de sobrecarga es permitido solo por regulación.
(2) Standby power (ISO 3046 Fuel Stop pwer): es la potencia máxima disponible para empleo bajo cargas variables por número limitado de horas año (500h) dentro de los siguientes limites máximos de funcionamiento: 100% de carga 25h/año – 90% de la carga 200h/año. No existe sobrecarga. Es aplicable en caso de interrupción de la distribución en zonas de red eléctrica confiable.